Laserfiche WebLink
<br />C. Illuminance: Table 1 is provided as a qeneral synopsis of the illumination level requirements <br />provided in the text. In the event of a conflict between the table and the text, the text controls. <br /> <br />Table 1: Illuminance Levels <br /> <br /> Location Maximum Illumination Averaae Illumination <br /> (foot-candlesl (foot-candles I <br />1 Parkinq Lot 5.0 2,5 <br /> Perimeter Parkinn 3.0 1.5 <br />2 Prooertv Boundarv 0.5 <br /> Adiacent to Residential 0.5 <br /> Aooroach and Drivewavs 1.5 <br /> Wlin 10ft. of driveway at orooertv line 0.5 <br />3 Accessorv Uses 3.0 <br /> Within 15 ft. of residential 0.5 <br /> Within 15 ft. of non-residential 1.0 <br /> Within 15 ft. of annroach 1.5 <br />4 Canonies drive-thru overhanqs 50.0 30.0 <br />5 Buildinn exteriors 5.0 <br />6 Streets Roadwavs <br /> Local 0.7 <br /> Collector 0.9 <br /> Arterial 1.6 <br />7 Soecialtv Liahtina <br /> Vehicle Disolav Lots - Front Row 15,0 10.0 <br /> All ouroose snorts field 40.0 <br /> Golf Drivina Ranne at tee 20.0 <br /> Basketball Vollevball 20.0 <br /> Tennis 50.0 <br /> <br />1. Parkinq Lots. Liqhtinq for commercial, industrial, office and multi-family parkinq lots shall <br />meet the followinq additional criteria: <br />a. The maximum illuminance shall be 5 foot-candles with an averaqe of 2.5 foot-candles. <br />b. Illuminance shall be 0.5 foot-candles at the property boundary. Approach and driveway <br />liohtinq may be 1.5 foot-candles. This illuminance must be reduced to 0.5 foot-candles <br />within 10 feet of the approach or driveway alonq the property line. <br />2. Canopy: <br />a, Under-liqhtinq of all canopies shall be no more than a maximum illuminance of 50 foot- <br />candles with an averaqe illuminance of 30 foot-candles. <br /> <br />Page 9 of 14 <br />Ordinance 02-1046 <br />